Chemical Research in Chinese Universities ›› 2006, Vol. 22 ›› Issue (1): 21-24.

• Articles • Previous Articles     Next Articles

Solid Phase Extraction Chemiluminescence Determination of Methamidaphos on Vegetables

LI Xiao-zhou1, GUAN Ting-ting1, ZHOU Chi1, YIN Ji-qiu2, ZHANG Yi-hua1   

  1. 1. College of Chemistry, Jilin University, Changchun 130012, P.R. China;
    2. College of Inspection, Dalian Medical University, Dalian 116031, P.R. China
  • Received:2005-05-30 Online:2006-02-24 Published:2011-08-06

Abstract: The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI)-chemiluminescence(CL) method is described. The method is based on the enhancing effect of methamidaphos on the CL reaction of luminol with hydrogen peroxide in an alkaline solution. Under the optimal conditions, the CL intensity is linear to the methamidaphos mass concentration in a range of 0.2-13 Lg/mL(r=0.9992). The detection limit(3R) is 0.047 Lg/mL. The relative standard deviations for the analysis of three samples are 1.8%, 2.5% and 3.7%(n=5), respectively. The recovery is in a range of 90%-109% by the method. In this work, this method was successfully applied to the determination of the methamidaphos residue on some vegetable samples.

Key words: Chemiluminescence, Flow injection, Solid phase extraction, Methamidaphos