[an error occurred while processing this directive]

高等学校化学研究 ›› 2017, Vol. 33 ›› Issue (3): 354-359.doi: 10.1007/s40242-017-6402-9

• Articles • 上一篇    下一篇

Chemiluminescent Determination of Cyromazine in Milk Samples Using Copper (III) Chelate-Triton X-100 by Flow Injection Analysis

Muhammad ASGHAR, Mohammad YAQOOB, Abdul NABI   

  1. Department of Chemistry, University of Balochistan, Quetta 87300, Pakistan
  • 收稿日期:2016-09-29 修回日期:2016-11-04 出版日期:2017-06-01 发布日期:2017-04-05
  • 通讯作者: Mohammad YAQOOB,E-mail:yaqoob2001@hotmail.com E-mail:yaqoob2001@hotmail.com
  • 基金资助:

    Supported by the Project of the Higher Education Commission of Pakistan(No.20-2732/NRPU/R&D/HEC).

Chemiluminescent Determination of Cyromazine in Milk Samples Using Copper (III) Chelate-Triton X-100 by Flow Injection Analysis

Muhammad ASGHAR, Mohammad YAQOOB, Abdul NABI   

  1. Department of Chemistry, University of Balochistan, Quetta 87300, Pakistan
  • Received:2016-09-29 Revised:2016-11-04 Online:2017-06-01 Published:2017-04-05
  • Contact: 10.1007/s40242-017-6402-9 E-mail:yaqoob2001@hotmail.com
  • Supported by:

    Supported by the Project of the Higher Education Commission of Pakistan(No.20-2732/NRPU/R&D/HEC).

摘要:

Cyromazine(CYR) was determined in milk samples using copper(III) chelate-Triton X-100 chemilumi-nescence(CL) system associated with flow-injection(FI) in KOH medium. The relative CL intensity for CYR concentration was linear over the range of 5×10-4-10 μg/mL(R2=0.9990, n=11) with injection rate of 160 h-1 and the relative standard deviation(RSD, n=4) of 1.2%-2.6%. The limit of detection(LOD) for signal-to-noise ratio of 3 was 1.5×10-4 μg/mL. The influences of key chemical and physical parameters, some major fresh water ions at their maximum admissible concentrations and a number of pesticides were examined as potential interferences. The concentrations of CYR in spiked milk samples were successfully determined by the proposed method and the results were in good agreement with that of the previously reported HPLC method, having recovery range of (92%±4%)-(106%±2%). The possible CL reaction mechanism for copper(III) chelate-Triton X-100-CYR was also briefly discussed.

关键词: Chemiluminescence, Flow injection analysis, Cyromazine, Milk sample

Abstract:

Cyromazine(CYR) was determined in milk samples using copper(III) chelate-Triton X-100 chemilumi-nescence(CL) system associated with flow-injection(FI) in KOH medium. The relative CL intensity for CYR concentration was linear over the range of 5×10-4-10 μg/mL(R2=0.9990, n=11) with injection rate of 160 h-1 and the relative standard deviation(RSD, n=4) of 1.2%-2.6%. The limit of detection(LOD) for signal-to-noise ratio of 3 was 1.5×10-4 μg/mL. The influences of key chemical and physical parameters, some major fresh water ions at their maximum admissible concentrations and a number of pesticides were examined as potential interferences. The concentrations of CYR in spiked milk samples were successfully determined by the proposed method and the results were in good agreement with that of the previously reported HPLC method, having recovery range of (92%±4%)-(106%±2%). The possible CL reaction mechanism for copper(III) chelate-Triton X-100-CYR was also briefly discussed.

Key words: Chemiluminescence, Flow injection analysis, Cyromazine, Milk sample